Low Voltage AC Frequency Inverter Drive Three Phase VFD on Fan And Pumps
-
Payment
-
Origin
China Mainland
-
Minimum Order
1
-
Packing
Pieces
- Contact Now Start Order
- Description
Product Detail
Model NO.: AVF508 Series
Output Type: Single & Three Phase
Switch Mode: PWM Control
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Nature of DC Power: Voltage Variable-Frequency Drive
Brand: Aubo
Output Voltage:0~220V/380VAC
Output Frequency: 0~600Hz
Transport Package: Less than 22kw by Cartons/ Piece;More than 22kw by Wooden /Piece
Origin: China
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Principle of Work: V/F Control Transducer
Main Circuit Type: Voltage
Link of Transformation: AC-DC-AC Variable-Frequency Drive
Function: Simple Type
Input Voltage: 220V/380V/440V
Output Power: 0.7~4.0kw
Output Current: 4.7~8.5A
Trademark: Aubo
Specification: CE,ISO9001,CCC
Basic Info
Product Description
AVF508 series Low Voltage VFD has the following features:
Multiple Control Modes:
*Supports multiple control modes: vector V/F control, sensorless vector speed control,
sensorless vector torque control, sensor vector speed control and sensor vector torque
control .
Advanced Vector Control Algorithm:
*The optimized VF control and sensorless vector control is more stable at low speed,
more powerful in the ability of low frequency torque output and with better dynamic
response and both the sensorless vector and sensor vector mode support speed
control and torque control.
Specifications:
Input and output | Featured Functions | ||
Input Voltage | 1AC 220~240V(±15%) 3AC 220~240V(±15%) 3AC 380~460V(±15%) | Featured Functions | Input&Output delay Flexible parameters display AVR(Automatic Volatage Regulation) Timing Control,fixed length control, etc. Simple PLC,16-Steeps Speed control Torque control bulit-in S curve acceleration.deceleration Mulit functional programmable keypad V/f separated control |
Input Frequency | 50Hz/60Hz±5%) | ||
Output Voltage | 0~input voltage, deviation<±3% | ||
Output Frequency | 0~3200Hz | ||
Control Characteristics | |||
Control mode | V/F control Sensor-less vector control Closed-loop vector control (CLVC) (+PG Card) | ||
Speed accuracy | ± 0.5%(V/F SVC) ± 0.02% (CLVC) | Environment Limitation | |
Speed fluctuaion | ± 0.5%(SVC) ± 0.02% (CLVC) | Install location | Without direct sunlight,free from dust, corrosive gas, oil mist,flammable gases,water vapor,water drop or salt, etc. |
Torque Response | <10ms( SVC) | Altitude | 0~2000m derated 1% for every 100m when the altitude is above 1000 meters |
Starting torque | 0.3Hz:150%(V/F SVC) 0 Hz:180% (CLVC) | Storage temperature | -20°C~+70°C |
Overload capacity | 150% Rated Current 60s 180% Rated Current 3s 200% Rated Current1s | Relative Humidity | 5~95%, no condensation |
Simple PLC Multi-step speed | 16steps speed External digital signal control Internal lock | ||
PID function | Standard build-in | ||
Communication | Modbus Canopen/Canbus(PG card) |
Products Construction
AVF508 series Low Voltage VFDs are Used on Fan And Pumps
1, Load feature
(1) Both of them belong to fluid control.
(2) If without VFD, the fluid is controlled by valve or baffles;
(3) For less fluid required system, there will be more energy saving.
(4) In theory, if the running frequency is H1, then
Energy Saving = 1-(H1/50)3
2, Requests for frequency inverters (VFD)
(1) Soft start the motor, reduce the surge current.
(2) VFD should work continuously without fault.
(3) Speed tracking and start (flying start) function should be reliable.
(4) In some systems, PID function is required.
3, Real example
In a hotel, there is an central air-conditioner, the cooling fan is one PCS of 15kW motor, in one year,
it runs 4000h, 2000h with the air flow of 85%, 2000h with the air flow of 60%.
4, Typical wiring diagram
Our Service:
1. Can I get some samples?
Yes, Sample order is available for quality check and market test .But you have to pay for it .
2. What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order .
3. What's your payment terms?
We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.Cash.
4. What's your warranty terms?
We offer 12 months warranty time .
5. Do you have the products in stock?
Depends on your request ,We have standard models in stock. Some special products and big order will be newly produced according to your order .
6. Can I mix different power in one container .
Yes ,Different models can be mixed up in one container ,even one order .
7. How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .every product will be fully assembled and carefully tested before packing and shipping .
8. Can you sell spare parts ?
If you are using our products .we can sell spare parts to you .
9.I would like to know if you have a partner for export?
Yes .We have the right to export and can sell electrical product all over the world..
10. Can you make the inverter and soft starter control boards (switchgear)?
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request .
11.Can the inverter connect with computer?
Yes .All inverters have built-in RS485 port .and support Modbus communication protocol.
12.How can I trust you ?
Our company has been audited and approved ISO9001,CE.CCC. Assessment report will could be sent to you by e-mail. and we will take all the responsibility once problem during warranty time.
- PLC Automatic Control 5 Pieces / (Min. Order)
- China Brand 3 Phase Inverter Vfd For Pump And Motor 1 Pieces / (Min. Order)
- High-perfomance Mini Variable Frequency Drive 380v 3phase Vfd 1 Pieces / (Min. Order)
- AC to AC Drive, 380V Frequency Inverter, VFD AC Drive 1 Pieces / (Min. Order)
- 10000V Inverter Medium Voltage VFD for Centrifugal Pump 1 Pieces / (Min. Order)